SciRepID - Scientific Publication Search

Publication Search

35,802 articles from 393 journals · 1,447 citations tracked

Showing 1-6 of 6

Analytics

Tri Wahyuni Kusuma Anggun; Viviana Kurnianingsih; Yuliana Intan Cayani; Ivana Azaria Widy; Hira Awali Nurmalinda +3 more

FUNDAMENTUM : Jurnal Pengabdian Multidisiplin 2026 Asosiasi Peneliti Dan Pengajar Ilmu Sosial Indonesia

The microbiological quality of clean water in Dusun Kepuhan has not met regulatory standards, posing potential health risks to the community. Laboratory examination identified Escherichia coli at 21 CFU/100 mL and total coliform bacteria at 180 CFU/100 mL, exceeding the permissible limits established by the Indonesian Ministry of Health Regulation No. 2 of 2023. This community service program was conducted to enhance residents’ knowledge and practical skills in managing clean water through the application of a chlorine diffuser as a simple and practical disinfection method. The implementation process included problem identification, coordination with the local PAMSIMAS management, educational sessions, and hands-on demonstrations of diffuser preparation and use. Program effectiveness was evaluated using pre-test and post-test assessments involving 30 participants. The findings indicated a statistically significant improvement in participants knowledge following the training. The chlorine diffuser approach was considered appropriate for the community setting due to its ease of use, affordability, and gradual chlorine release mechanism. Continuous monitoring and sustained community commitment are necessary to ensure long-term implementation of safe water disinfection practices.

Ririn Mulyani; Alfiya Rokhmah; Fajar Anzari

Teknik: Jurnal Ilmu Teknik dan Informatika 2025 LPPM Sekolah Tinggi Ilmu Ekonomi - Studi Ekonomi Modern

. PT. XY is a company engaged in the printing sector, especially in the security products sector, which is required to process its wastewater so that it can meet the required wastewater quality standards, especially in the processing of domestic waste originating from human waste and other consumption waste such as washing water, rinsing and so on. A Sewage Treatment Plant is a domestic liquid waste processing installation to process residual domestic liquid waste so that it becomes clear and is no longer harmful to the environment. The problem that arises is one of the measurement parameters in the wastewater quality standard, namely total coliform (coliform bacteria), which has not met the requirements for several months. This study aims to process domestic waste in the sewage treatment plant process with the six-sigma method to achieve results according to the requirements of the liquid waste quality standard. It is safe to be discharged into water bodies. The results of this study from 6 parameters 5 parameters meet the wastewater quality standards, namely: pH, Total Suspended Solids / TSS, Biochemical Oxygen Demand5 / BOD5, Chemical Oxygen Demand / COD, Oil and fat, while the average level of Total Coliform in a year is 6,448 MPN / 100 ml, not yet meeting the wastewater quality standards of 3,000 MPN / 100 ml. The results of the six-sigma calculation found a result of 1.5 Sigma (σ) where the process is in the non-competitive category

Putri Aprillia Wijayanti; Yayok Suryo Purnomo

Venus: Jurnal Publikasi Rumpun Ilmu Teknik 2025 Asosiasi Riset Ilmu Teknik Indonesia

This study aims to evaluate the performance of the Sewage Treatment Plant (STP) at PT PLN Nusantara Power Unit Pembangkitan Gresik in reducing pollutant loads from domestic wastewater. The evaluation involves analyzing water quality parameters including pH, BOD, COD, TSS, oil and grease, total ammonia, and total coliform at both inlet and outlet of the STP. Additionally, the actual daily discharge was observed and compared to the design capacity to assess operational efficiency. The method used was descriptive qualitative, involving field observation, documentation, and laboratory test data analysis during the January–March 2025 period. The results show that all outlet parameters met the effluent standards set by Regulation No. 68/2016 of the Ministry of Environment and Forestry. However, the actual flow rate, which is only 1.6–3.3% of the design capacity, indicates potential inefficiencies in energy use and biological processes. Therefore, operational adjustments and optimization of STP capacity utilization are necessary for more efficient and sustainable system performance.

Muhammad Abdus Salam Jawwad; Nuraini Safitri

Globe: Publikasi Ilmu Teknik, Teknologi Kebumian, Ilmu Perkapalan 2025 Asosiasi Riset Ilmu Teknik Indonesia

PT X is a chemical manufacturing company specializing in the production of phosphoric acid and sulfuric acid. In addition to waste generated from production processes, PT X also produces domestic wastewater originating from supporting activities such as employee barracks, offices, and laundry facilities. This domestic wastewater contains parameters that can potentially pollute the environment, such as BOD, COD, TSS, ammonia, and Total Coliform, some of which exceed the quality standards set by the Minister of Environment Regulation No. 68 of 2016. This study aims to design an effective Domestic Wastewater Treatment Plant (DWTP) system to process the domestic wastewater of PT X. The proposed DWTP system consists of a collection tank, Anaerobic Baffled Reactor (ABR), Aerobic Biofilter, and disinfection unit. Each unit is designed to reduce pollutant parameters to meet quality standards. Based on the calculations, this system can handle a wastewater flow rate of 21.91 m³/day with high treatment efficiency for critical parameters. The study results indicate that the proposed DWTP design can reduce environmental pollution, improve wastewater treatment operational efficiency, and comply with applicable regulations. Implementing this system is highly recommended to ensure environmental sustainability and the continued operations of PT X.

Fibrinika Tuta Setiani; Anang Kurniawan

International Journal of Public Health 2024 Asosiasi Riset Ilmu Kesehatan Indonesia

Introduction: Water quality parameters are indicated by the presence of E. coli bacteria. These bacteria come from human feces, warm-blooded animals, and non-fecal coliforms. Decree of the Health Minister of the Republic of Indonesia Number 907/MENKES/VII/2002 concerning requirements and supervision of drinking water quality states that good drinking water has a zero total coliform and fecal coliform. Methods: This research uses a descriptive approach with a cross-sectional design. It aims to determine the quality of water sources in Sulkatan village. Ten (10) water sources were used as the samples using total sampling method. The collected samples were then taken to the laboratory to be tested with a series of MPN tests Results and Discussion: The results show that the amount of Escherichia coli bacteria in water samples in Sulkatan Village is 0MPN/100 ml. It is owing to the location of the water source that is far from industrial activities, household waste and residential areas. Conclusion: The quality of the tested well-water samples is good and within normal limits in accordance with the Decree of the Health Minister of the Republic of Indonesia Number 907/MENKES/VII/2002    

Muhammad Aditya Muzaky; Rizka Novembrianto

Jurnal Universal Technic (UNITECH) 2024 Fakultas Teknik Universitas Maritim AMNI Semarang

In the wastewater industry, it is divided into 2, specifically wastewater from home activities and production. Domestic activity wastewater comes from all worker sanitation activities and industrial supporting facilities such as prayer rooms, canteens and toilets. Waste water from these activities must be treated first so that it does not pollute the surrounding environment. PT X is an industry that operates in the field of bulk LPG filling stations which has made efforts to process and also utilize 100% of the waste water from its domestic activities. Sewage Treatment Plants handle the processing (STP) facilities with chemical and biological processes which are able to reduce pollutant parameters such as BOD, COD, TSS, Ammonia and Total Coliform by 90%, 85%, 95%, 90% and 99.9% and have been meet the specified quality standards. Meanwhile, oil & fat parameters are not too focused because they still meet existing quality standards, Therefore, processing aims to lower the relatively high organic characteristics. The results of this processing will be reused to reduce the use of clean water for irrigating green open spaces and roads.