Publication Search

74,541 articles from 728 journals · 2,111 citations tracked

Showing 1-9 of 9

Analytics

Falah Faustabi Akbar; Esti Wulandari; Dika Ayu Safitri

Jurnal Riset Rumpun Ilmu Teknik 2026 Pusat riset dan Inovasi Nasional

Rapid population growth in Sidoarjo Regency has triggered massive land-use changes, resulting in increased surface runoff and reduced performance of the drainage system. This study aims to evaluate the hydraulic capacity of drainage channels in the Pondok Sidokare Indah Housing area against design flood discharges with return periods of 2, 5, and 10 years. The method used is a descriptive quantitative approach, involving hydrological analysis using maximum daily rainfall data from 2015–2025 and hydraulic modeling of the existing channel along 350 meters. The frequency analysis results indicate that the Log Pearson Type III distribution is the most suitable method based on statistical parameters and the Smirnov-Kolmogorov goodness-of-fit test. The calculation of design flood discharge using the rational method yields values of 0.749 m³/s (2-year), 1.003 m³/s (5-year), and 1.164 m³/s (10-year). Meanwhile, the maximum capacity of the existing channel ranges only between 0.534 m³/s and 0.733 m³/s. The comparison between hydrological load and channel capacity shows that all observation points (Sta 0+000 to Sta 0+350) are in overflow condition, even for the lowest return period flood discharge. This condition confirms that the current channel dimensions are no longer adequate and require normalization to mitigate annual flooding in the area.

Ujang Wiharja; Muhammad Faqih

Jupiter: Publikasi Ilmu Keteknikan Industri, Teknik Elektro dan Informatika 2025 Asosiasi Riset Ilmu Teknik Indonesia

Transmission line reconductoring is one of the strategic solutions to increase the capacity and efficiency of the power system without the need to build new infrastructure. This study aims to analyze and compare the performance of two types of conductors, namely ACSR Hawk and ACCC Amsterdam, used in the Suralaya-Cilegon 500 kV SUTET transmission line. The comparison is carried out by considering technical aspects including power losses, ampacity, horizontal and vertical sag values, and overall energy efficiency. The research methodology involved a literature study, collection of conductor technical data, calculation of resistance, current, and power losses, and simulation of sag values against temperature variations. In addition, economic analysis and field implementation aspects were also considered to assess the feasibility of using each conductor. The results show that Amsterdam's ACCC conductor has superior technical performance compared to Hawk's ACSR. ACCC is capable of delivering currents up to ±1300 A, compared to ACSR Hawk which is only ±800 A. The power loss value using ACCC is recorded at ±1.34 MW, lower than ACSR Hawk at ±1.79 MW. In addition, ACCC exhibits smaller sag values due to its lighter weight and higher tensile stress, making it more stable against temperature fluctuations. In terms of energy efficiency, the use of ACCC can save energy up to ±3942 MWh per year. By considering the technical advantages and long-term energy efficiency, this study recommends the use of Amsterdam ACCC as a reconductoring solution for high-voltage transmission lines, especially in systems that have high loads and require maximum reliability and efficiency.

Ari Purnomo Aji; Denny Irawan; Rini Puji Astutik

Uranus: Jurnal Ilmiah Teknik Elektro, Sains dan Informatika 2025 Asosiasi Riset Teknik Elektro dan Informatika Indonesia

PLN as an electricity provider that serves all regions in Indonesia certainly always wants to provide the best service to its consumers, including PT. PLN Persero UP3 Gresik. Along with the increase in consumers, the company continues to develop distribution lines, however, because the addition of more and more lines makes the distribution cables longer and the load becomes greater, resulting in voltage drops and power factors decreasing in several feeders, including in the feeder network. LOWAYU, causing poor power quality.This research aims to find and obtain the magnitude of the power flow which includes active power, reactive power, apparent power and the magnitude of the power losses (losses) contained in the LOWAYU feeder network, the magnitude of the voltage and voltage drop on each bus on the network. LOWAYU feeder using the backward-forward method. And determine the value of reactive power required for the capacitor on each bus that experiences a voltage drop. Then a comparison will be made between the results of manual calculations using the backward-forward method and the results of simulation data using ETAP Power Station 19.0.1 software.From this research, it can be seen that the safe limit for the voltage drop value is still below 5% or above 5%, so it is necessary to add capacitor banks to improve the power factor and reduce the voltage drop value on distribution network buses that experience voltage drops.

Nindia Puspa Ashari; Diana Alia; Eddi Eddi; Henna Nurdiansari; Renta Novaliana

Jupiter: Publikasi Ilmu Keteknikan Industri, Teknik Elektro dan Informatika 2024 Asosiasi Riset Ilmu Teknik Indonesia

Freon is one of the refrigerants used in refrigeration systems. The refrigeration system has a very important role, namely to preserve food ingredients so that food can last longer. The use of freon is not only used in ships but is widely found in home appliances in refrigeration systems used in freezers, air conditioners, refrigerators, and dispensers. If more freon is used, the negative impact that arises is greater, namely the depletion of the ozone layer and global warming which can have a bad influence on health, the life of living things and the environment. The purpose of this researcher is to create a tool to reduce the negative impact of freon use, namely by using peltier as a cooling medium with environmentally friendly thermoelectric modules. This study uses trial and error methods. Where the trial process is carried out by turning on one of the working push buttons and observing the temperature value. Then it is processed by the control system, namely Arduino Mega which will later provide a PWM output signal to the IRF540 mosfet when the output temperature value is in line with the reference value and vice versa. The test of this tool was carried out by comparing measurements between the author's prototype tool and the standard measuring tool, namely the digital thermometer. Based on the test results, this device can produce a minimum temperature of 140C at 30-minute intervals without any media. The trial using 330ml bottled water can reach a temperature of 170C within 30 minutes in the cooler box. This tool is also equipped with an automatic monitoring system using a PWM signal in the form of a change in fan speed, which is 255 RPS maximum speed and when getting a PWM signal it changes to 50 RPS. The percentage of errors resulting from the comparison of standard measuring instruments and sensor values had the highest and lowest percentages of 2.37% and 0.84% in cold dispersion conditions without charge. Then the highest and lowest error percentages were 1.69% and 0.72% in the state of containing a load of 1 330ml mineral bottle. This ptototype uses data recording using Micro-SD as a data logger.

Nur Sabrina Rambe; Darlina Tanjung; M Husni Malik Hasibuan; Afdhal Hubbig

Konstruksi: Publikasi Ilmu Teknik, Perencanaan Tata Ruang dan Teknik Sipil 2024 Asosiasi Riset Ilmu Teknik Indonesia

An anchor is a steel element that is embedded in concrete when it is cast (cast in place) or installed later (post-installed) into concrete that has hardened and is used to distribute loads (tension and shear) acting on the concrete (SNI 2847:2019). The use of anchors in the world of construction is increasingly popular to help connect concrete structures. The installation of anchors has progressed from the initial anchors being installed before casting the concrete (cast in place), progressing to the anchors being installed after the concrete has hardened (post installed) by drilling. By drilling into concrete, installing and removing anchors becomes easier. Installation of cast-in-place anchors is generally used in the design of new construction, while post-installed anchor installation is generally used in old construction for repairs or retrofitting. Anchors have several variations including hed heax, L bolt and J bolt anchor variations, but it is not yet known which anchor variation has a greater bond strength value, what are the results of the comparison of bond strength values ​​for each variation of anchor and what are the differences in the anchor bond strength capacity for each variation? the anchor. With this research, it is hoped that we can find out the bond strength and bond stress values ​​for each variation of anchor so that the comparison of the bond strength of the anchor can answer the differences in capacity of each variation of the anchor as well. Research on the bond strength of anchors based on variations in anchor shape using the cast in place method shows that the bond strength value shown at the highest loading value is the type J anchor variation with an average load of 27,816 kN, the type L anchor variation with an average load of 26,971 kN and variations of the hex head type anchor with an average load of 12.85 kN. It can be concluded that the stress value is directly proportional to the loading value. The greater the loading value, the greater the bond stress value. The highest bond stress value is found in the type J anchor variation with an average bond stress value of 151,397 Mpa, in the L type anchor variation with an average bond stress value of 147,798 Mpa and in the hex head type anchor variation with an average bond stress value of 69.953 Mpa, so the bond stress is directly proportional to the loading value.

Bayu Despriyanto Pratama; Martunus Juddin; Kusumaning Tyas

Inovasi Kesehatan Global 2024 Lembaga Pengembangan Kinerja Dosen

Background: General anesthesia is the act of administering a combination of drugs during surgery with the aim of reducing consciousness and eliminating pain in the patient. There are 2.5% of patients experiencing intra-anesthesia complications including hypotension.Objective: To determine the comparison of giving fluid loading and reducing inhaled gas with giving ephedrine to prevent hypotension in patients in central surgery installations.Research Metod: Quantitative method with experimental research type with quasi-experiment. This research used a Pretest-Posttest Two Group Design with 22 respondents.Research Result: Based on test statistics, it is known that the results of the Independent Sample T Test data analysis test show a P value (>0.05), namely H0 is accepted. Based on this test, it was concluded that there was no significant relationship between administering fluid loading and reducing inhaled gas with administering ephedrine to prevent hypotension.Conclusion: Based on this research, researchers are more effective in using fluid loading and reducing inhaled gas than administering ephedrine in the ETT technique for general anesthesia.

Tang, Nguyen Anh; Cuong, Nguyen Minh Duc

Journal of Computing Theories and Applications 2023 Universitas Dian Nuswantoro

This study focuses on solving the green economic load dispatch problem by considering the presence of green energy sources, including wind energy and solar power plants. The main objective function of the whole study is to minimize the total fuel cost (TFC) of all the thermal generating sources (TGSs) in the system. Moreover, the multiple selection of all TGSs is also evaluated. Fire hawk optimization (FHO) and the Zebra optimization algorithm (ZOA) are applied to solve the problem of achieving the best TFC value and satisfying all the constraints involved. The results indicated that ZOA can achieve a better optimal solution compared to FHO. Particularly, the results obtained by ZOA are completely superior to FHO in all comparison criteria at two load demand levels, such as Best TFC value (Best.Cost), Average TFC value (Aver.Cost), and Maximum TFC value (Max.Cost). On top of that, ZOA is the only algorithm of two applied ones providing the fast convergence capability to the optimal value of the main objective functions in two cases of load demand levels. Therefore, ZOA is an efficient search method to deal with such GELD problems.

M.Rossy Rakasiwi; Nurul Istiqomah; Kusumaning Tyas

Jurnal Rumpun Ilmu Kesehatan 2022 Pusat Riset dan Inovasi Nasional

Background: General anesthesia is the act of administering a combination of drugs during surgery with the aim of reducing consciousness and eliminating pain in the patient. There are 2.5% of patients experiencing intra-anesthesia complications including hypotension.Objective: To determine the comparison of giving fluid loading and reducing inhaled gas with giving ephedrine to prevent hypotension in patients in central surgery installations.Research Metod: Quantitative method with experimental research type with quasi-experiment. This research used a Pretest-Posttest Two Group Design with 22 respondents.Research Result: Based on test statistics, it is known that the results of the Independent Sample T Test data analysis test show a P value (>0.05), namely H0 is accepted. Based on this test, it was concluded that there was no significant relationship between administering fluid loading and reducing inhaled gas with administering ephedrine to prevent hypotension.Conclusion: Based on this research, researchers are more effective in using fluid loading and reducing inhaled gas than administering ephedrine in the ETT technique for general anesthesia.

Agus Wibowo; Lawrence Adi Supriyono

Jurnal Elektronika dan Komputer 2019 STEKOM PRESS

The development of microcontroller technology that is rapidly making applications to be developed as a work in the field of technology that can help and facilitate human activities. Researchers see that current technological developments there are many uses of loadcell sensors to detect weight on objects. The number of factors that affect the weight difference between digital scales and scales very significant conventional. Therefore researchers analyzed the use of loadcell sensors for calculate solid and liquid objects and analyze the work system and the accuracy of the accuracy on the loadcell sensor in calculating the weight of solid objects and liquid objects.