SciRepID - Scientific Publication Search

Publication Search

50,562 articles from 425 journals · 1,447 citations tracked

Showing 1-8 of 8

Analytics

Dea Raivani Claresta Hamzah; Restu Hikmah Ayu Murti; Yubi Fatroh Harianto

Venus: Jurnal Publikasi Rumpun Ilmu Teknik 2025 Asosiasi Riset Ilmu Teknik Indonesia

This study aims to evaluate the effectiveness of various doses of 6.25% Poly Aluminium Chloride (PAC) and 0.1% polymer flocculant in reducing Total Suspended Solids (TSS) and assessing pH changes in coal stockpile wastewater at PT PLN Nusantara Power UP Paiton Unit 9. Stockpile wastewater typically contains high levels of suspended solids originating from water spray activities that carry fine coal particles. The coagulation–flocculation process was performed using the jar test method with PAC dosages of 35 ppm, 50 ppm, and 65 ppm, along with flocculant dosages of 6 ppm and 7 ppm. pH and TSS were analyzed before and after treatment to assess process effectiveness. The results indicate that a PAC dosage of 35 ppm combined with a 6 ppm flocculant achieved the highest TSS removal efficiency of 98.15%. Increasing PAC dosage resulted in reduced performance due to overdosing effects, leading to charge destabilization and impaired floc formation. These findings highlight the importance of optimizing coagulant dosage to improve stockpile wastewater quality for safe reuse in operational activities.

Priyadi Yahya; Rachmah Nanda Kartika; Yoga Putra Pratama

Jurnal Riset Rumpun Ilmu Teknik 2025 Pusat riset dan Inovasi Nasional

The impacts of wastewater (liquid waste) include contamination and pollution of surface water and other water bodies utilized by humans, as well as disruption to aquatic life. Wastewater generated from plate washing processes in offset printing industries contains toxic substances that can harm the environment, such as ink pigments, additives, alcohol, and other hazardous chemicals. This study aims to reduce the environmental impact caused by plate washing wastewater. The method used in this research is the Jar Test, which is commonly applied to evaluate the effectiveness of coagulants in water and wastewater treatment. Based on the findings, this method successfully reduced the Total Dissolved Solids (TDS) level by 18%. These results indicate that the use of alum as a coagulant has a significant effect on altering the chemical composition of the plate washing wastewater, thereby contributing to pollution reduction

Muhammad Rezky Wahyudi; Hidayatur Rizky; Ufaul Apriani; Nor Latifah

Jurnal ilmu Kesehatan Umum 2025 Asosiasi Riset Ilmu Kesehatan Indonesia

The pharmaceutical industry produces solid, liquid, and gaseous waste containing active pharmaceutical ingredients that pose serious environmental risks. These wastes can disrupt ecosystems and accelerate antimicrobial resistance. This systematic literature review examines pharmaceutical waste concepts, classifications, characteristics, and relevant regulatory frameworks. It also addresses ecotoxicological effects on aquatic and terrestrial ecosystems, antibiotic contamination and resistance, water and soil pollution, treatment technologies, industrial policies, and best practices. Findings show that conventional wastewater treatment is largely ineffective at removing pharmaceutical residues, resulting in their presence in surface water, soil, and even drinking water. Compounds such as β-blockers, cytostatics, antibiotics, and hormones harm aquatic life by impairing reproduction and causing mutations. Antibiotic-laden industrial waste contributes to the emergence of resistant bacteria. Recommended treatment methods include biothermal processes, advanced oxidation (e.g., UV/H₂O₂, ozonation), adsorption (activated carbon), coagulation-flocculation, and controlled incineration. Stronger enforcement of hazardous waste regulations (e.g., Government Regulation No. 101/2014, Ministry of Environment and Forestry Regulation No. 56/2015) and adherence to WHO (2025) guidelines are essential. In conclusion, multisectoral collaboration (One Health), improved waste treatment capacity, and adoption of best practices are crucial to preventing pharmaceutical pollution and promoting environmental sustainability.

Mutiara Saniyyah Rochmasia; Yayok Suryo Purnomo; Berta Ryza Harsativa; Arleen Maranatha Siahaan

Venus: Jurnal Publikasi Rumpun Ilmu Teknik 2025 Asosiasi Riset Ilmu Teknik Indonesia

Using a descriptive method with a triangulation approach including observation, document analysis, and interviews this study ensures data reliability. Daily monitoring is conducted on wastewater flow and pH levels, while monthly laboratory analysis covers eight key parameters: Total Suspended Solids (TSS), iron (Fe), copper (Cu), zinc (Zn), total chromium (Cr), phosphate (PO³), oil and grease, and pH to evaluate the perfomance of the treatment system. The treatment process begins with the inflow of 960 m³ of wastewater per day into the storage pond, where aeration is applied to ensure homogenization before being transferred to the neutralization unit. pH adjustment is carried out by adding NaOH or HCl before the wastewater undergoes coagulation and flocculation stages. The study’s findings indicate that the WWTP meets the environmental quality standards established in accordance with the Decree of the Head of the Investment Coordinating Board of the Republic of Indonesia (2020), Number SK.214/1/KLHK/2020 concerning the Permit for Wastewater Disposal into the Sea on Behalf of PT Pembangkit Jawa Bali Unit Pembangkitan Gresik. This study emphasizes the importance of systematic monitoring and treatment in wastewater management.

Awaliah Rahmat

Journal of Educational Innovation and Public Health 2025 Pusat Riset dan Inovasi Nasional

The presence of heavy metals in waste is one of the variables that can pollute and damage the environment. Lead is one of the chemical contents that can be found in hospital liquid waste. Hospital liquid waste comes from work unit processes throughout the hospital environment which contains dangerous chemicals so it needs to be processed before being discharged into the environment. Research has been carried out using the coagulation-flocculation method using sugar palm seeds as a biocoagulant. The aim of this research is to find out how the palm seed coagulant mass influences in reducing lead (Pb) levels. hospital wastewater with the addition of variations in coagulant mass, namely 0.3%, 0.4%, 0.5%, 0.6% and 0.7%. From the filtrate resulting from coagulation-flocculation which was then analyzed based on the Regulation of the Minister of Environment and Forestry of the Republic of Indonesia Number P.68 of 2016 concerning Domestic Wastewater Quality Standards, from the results of this research it is known that sugar palm seeds as a biocoagulant are able to reduce the most optimal PB concentration when the coagulant concentration is added to 0.6%.

Ramiza Firyal Tuffahati; Rizka Novembrianto

Venus: Jurnal Publikasi Rumpun Ilmu Teknik 2024 Asosiasi Riset Ilmu Teknik Indonesia

Indonesia's cigarette industry has experienced significant growth, contributing substantially to economic development and work opportunities. However, the production process generates wastewater containing pollutants like BOD, COD, TSS, NH3-N, phenol, and pH imbalances, which pose environmental risks. This study aims to evaluate the quality of wastewater from the cigarette industry and analyze the treatment technologies used to meet environmental standards. Using qualitative methods and secondary data from relevant industries, the research shows that cigarette industry wastewater is highly polluted and requires multiple treatment stages before being discharged into surface water. Key technologies include collecting tanks, equalization tanks, coagulation-flocculation, clarifiers, and trickling filters. The findings provide valuable insights into waste management challenges and propose solutions to support environmental sustainability in the cigarette industry.

Putri Cahyaning Sri Hartini; Munawar Ali

Venus: Jurnal Publikasi Rumpun Ilmu Teknik 2024 Asosiasi Riset Ilmu Teknik Indonesia

Sludge is a by-product of an activity that comes from the discharge outlet of the flocculation, sedimentation and backwash filtration basins. To determine the volume of sludge contained in one liter of raw water, it is necessary to conduct a Jartest Test by determining the optimum dose of PAC. This water sampling was carried out at the Krian 1 Water Treatment Plant (IPA). Primary data collection is obtained from Imhoff Cone Results data. While for secondary data collection we get from Jartest data.  The manufacture of the coagulant solution used is Poly Aluminum Chloride (PAC). The average turbidity value in February was around 123 NTU and there was an increase in turbidity on the seventh day which reached 237 NTU. The drastic increase in turbidity reached 455 NTU with an average turbidity in March of 130 NTU. The graph shows that there is a significant correlation between the volume of sludge produced during the treatment process and the level of water turbidity. Thus, the researcher suggests further treatment of the remaining sludge which can be done by making a Sludge Drying Bed (SDB).  

Sofianti Sofianti; Ardiansyah Ardiansyah; Susaldi Susaldi

Student Scientific Creativity Journal 2023 Pusat Riset dan Inovasi Nasional

The existence of the cosmetics industry basically has a positive impact but also creates new problems because there is still inadequate management of liquid waste. The aim of the study was to find out how the coagulation and flocculation processes affect the quality of BOD, COD, and TSS in wastewater treatment plants. This research method uses a qualitative type method, based on its type with a cross sectional approach with an observational researchhmethode. The populationnof this study is the outlet of the Wastewater Treatment Plant which has undergone coagulation and flocculation processes. The samples used were outlets after the coagulation and flocculation processes were carried out at the WWTP in Cosmetic Industry X, Depok City. The results from the inlet levels of BOD 2,152 mg/l, COD 5,380 mg/l, and TSS 1,830 mg/l. The outlet levels of the Cosmetic Industry X Wastewater Treatment Installation in Depok City showed a BOD level of 15 mg/l, a COD level of 63 mg/l, and a TSS of 20 mg/l. In this study the contents of BOD, COD and TSS in cosmetic industry waste X in Depok city were included in the water quality status with good quality after coagulation and flocculation processes.