Hadiyanto, Gunawan

Jurnal Elektronika dan Komputer 2021 STEKOM PRESS

The infrared detector (or IR detector) is an optoelectronic component and represents the core element of gas analyzers, flame sensors, devices of spectral analysis, as well as non-contact temperature measurement. pyroelectric infrared detectors work with  stabilization time  in a wide operating temperature range (-55 ... 85) °C, capable of measuring the slightest amounts of infrared radiation (as little as a fraction of a nW) with wavelengths between 1 µm and > 25 µm. The difference of the good pyroelectric or No good (NG) devices shown by graph of voltage offset operating that can check by manual using Digital Multi Meter or semi auto by using microcontroller One of importance measuring of IRD sensors  is Offset Voltage, stabilization of offset voltage indicate the sensor is stable with certain level value. Stabilization value measurement during measuring time means the average value not so much different with fluctuation value.  10 bit ADC on Atmega 328 that main microcontroller on Arduino Uno is capable to measure the Offset Voltage of IRD sensor and check the measurement values is within specification of IRD sensor.

ABA, Muhammad Ulin Nuha; Bayu Wahyudi; Mohamad Sofie

Jurnal Elektronika dan Komputer 2021 STEKOM PRESS

The climatic chamber is a calibration medium for the thermohygrometer. This simple climatic chamber was built using the Arduino uno, DHT22 sensor, heater, and peltier. The climatic chamber was designed and manufactured well and cheaply. Climatic chamber testing of the design results is carried out to determine the success rate of the tool. Tests are carried out using the Madgetech data logger tool through monitoring or monitoring of temperature within a certain period of time. The results of temperature monitoring at two observed values, namely temperatures of 250C to 300C and temperatures of 300C to 350C, showed good results with the corresponding rhythm of temperature increase and temperature decrease. It's just that the decrease in temperature still takes longer than the increase in temperature. This shows that the heater can be said to be working optimally and the peltier is not fully working. So it is necessary to do further studies related to the peltier for the climatic chamber both in terms of number and characteristics.